Esta página aún no está disponible en su idioma. Mostrando inglés.

0 · About this manual

Product: Cydiance C1 — USB Single-Use Temperature Logger

Document version / date: v1.0 — 2026-08-13

Language: English

This is the complete C1 manual — suitable to hand to a new customer or attach to a shipment/customs file. For a short on-site reference, use C1 — For shippers and C1 — For receivers.
1 · Product overview

The C1 is Cydiance's standard USB temperature logger. It has no Bluetooth and no screen: one button starts recording; at destination you plug the USB connector in and the device writes PDF + CSV on board — no extra software required. Silent Records keeps a factory backup CSV if the shipper forgets to start.

Cydiance C1 — front view Cydiance 1 2 3 4
Front — Start & Mark button · Alarm LED · Working LED (level with the button) · USB Type-A
Cydiance C1 — back view
Back — keep the food-grade bag on until USB readout
Key specifications
ItemValue
SensorsInternal temperature only
ConnectivityUSB Type-A (onboard PDF + CSV; no Bluetooth)
Silent RecordsFactory backup CSV if start is missed
Temperature range−30°C to +70°C
Accuracy±0.5°C (0°C to 60°C); ±1°C elsewhere
Resolution0.1°C
Internal storage14,400 records
Typical interval / duration3 / 6 / 9 / 12 min → 30 / 60 / 90 / 120 days
StartPress and hold 5 seconds (both LEDs light)
StopAutomatic at data limit — manual stop is not available
Event marksUp to 8 (short-press while logging)
Time zoneDefault UTC+0; custom TZ requires MOQ
Status2 LEDs — Alarm + Working (see §1.1)
EnclosureFood-grade waterproof bag, IP67
Dimensions / weight60 × 30 mm card · 94 × 50 × 6 mm in bag · 14.5 g
Battery3.0V CR2032 lithium coin cell; 12-month shelf / service life
Response / calibrationUSP 1118, EN 12830; NIST-traceable (chip-level + PCBA 3-point AQL 0.25 General I)
Certifications (declared)CE, FCC-sDOC, RoHS

What's in the box: Device in its food-grade waterproof bag. Do not remove the bag until USB readout at destination.

1.1 Button and LEDs

One physical button. Hold to start; short-press to mark or to confirm the logger is still running. There is no stop gesture.

Action / stateWhat you see
Start — hold ~5 sBoth LEDs light — recording has started
First 30 minutesWorking LED (blue) blinks twice every 2 seconds
After 30 minutesLEDs go dark to save battery — this is normal
Status check — short pressLED blinks → still recording
MARK — short press while loggingWorking LED on for 1 second; up to 8 marks
Alarm LEDIndicates a temperature alarm / excursion (with Working LED for recording status)
Why no stop button? Field use showed accidental or premature stops before arrival. From late 2019 Cydiance removed manual stop: the logger runs until the 14,400-record limit. See Why is there no stop button?. Older printed C1 guides that describe a 5-second stop are obsolete.
2 · For shippers
Do not remove the plastic bag unless you need USB access for final readings. Keep the bag on during the whole trip (IP67).

2.1 Start the device

  1. Press and hold the button for 5 seconds until both LEDs light up.
  2. For the first 30 minutes the blue Working LED blinks twice every 2 seconds.
  3. After 30 minutes the LED stops blinking to save battery.
  4. To confirm the logger is still active, press the button once. If the LED blinks, it is running.
  5. While logging, a single press creates a MARK (blue LED on 1 second). You can make up to 8 marks.
  6. The logger cannot be stopped manually; it stops when the data limit is reached.

2.2 Place in the shipment

When possible, use two loggers for the simplest temperature mapping:

  1. Place one at the container air outlet to record supply-air temperature from the refrigeration unit.
  2. Place one at the container door to capture temperature coverage across the load.

Keep each logger in its plastic bag during transport.

2.3 Receiving side

If you are receiving the shipment, see §3. Short guide: C1 — For receivers.

Safety

Do not place the device near a fire — the battery can be dangerous.

Keep away from babies, children, and pets; this device is not a toy (coin-cell ingestion hazard).

Consider the recycling program before disposing of the device (currently China inbound take-back; contact support for other routes).

3 · For receivers

When the trip is complete, connect the logger by USB. PDF and CSV are generated on the device — no extra software required.

3.1 With a PC

  1. Remove the plastic bag if needed.
  2. Plug the USB connector into the computer.
  3. Wait until PDF and CSV files appear (typically under a minute).

3.2 With an Android phone

  1. Use a suitable USB OTG adapter.
  2. Plug in the logger and open the files from your file manager.

3.3 What is in the report

The onboard PDF is built from the full trip dataset (up to 14,400 points) so short temperature spikes stay visible — not a smoothed thumbnail. Summaries typically include maximum, minimum, average, and MKT (Mean Kinetic Temperature). Chart design notes: How are PDF charts built?. MKT use and limits: MKT. Silent Records: What is Silent Records?.

3.4 Optional — Cydiance Logger Reader (Windows)

Receiving desks that plug many USB loggers can run Cydiance Logger Reader: it watches USB, imports the CSV, and opens a local browser view. Not required for a single readout.

Shipping side: §2 or C1 — For shippers.

4 · Storage & operating conditions
ConditionRangeNotes
Measuring / operating temperature−30°C to +70°CExposure outside this range is a warranty exclusion (§7.2)
Accuracy window±0.5°C from 0°C to 60°C±1°C outside that window
Shelf life (label)12 monthsFrom manufacture; do not exceed before first use
Service life / battery warranty12 monthsPer device label
Ingress protectionIP67Keep the food-grade bag on in transit

Improper storage, installation, or shipment/container placement causing damage is not covered under warranty (see §7.2).

5 · Battery, safety & transport compliance

The C1 is powered by a built-in 3.0V CR2032 lithium metal coin cell. It is not user-replaceable. The cell is contained in the equipment (not shipped as a spare battery).

5.1 Battery specification

ItemValue
Battery typeLithium metal coin cell, CR2032, 3.0V
Lithium content< 0.3 g (well under the 1 g/cell Section II threshold)
Replaceable by user?No
Warranty12 months (label Shelf life / Service life)

5.2 Transport compliance

For air transport the C1 is treated as UN3091 — lithium metal batteries contained in equipment — under IATA DGR Packing Instruction 970 Section II. Most carriers accept Section II without a full dangerous-goods declaration when lithium content stays below 1 g/cell; confirm any operator variations with the airline. Sea: IMDG Code 2018 P903. This is the opposite case from the R3 (Ni-MH, not lithium).

5.3 What Cydiance can provide on request

  • Battery / UN3091 supporting letter for carrier or customs files
  • MSDS (Material Safety Data Sheet) summary
  • FCC-sDOC, CE and RoHS references, on request

5.4 Safety notes

  • Do not puncture, crush, drop, or incinerate the device.
  • Do not disassemble the device or attempt to replace the coin cell.
  • Keep away from children and pets — coin cells are an ingestion hazard.
  • Do not place near fire or operate outside the ranges in §4.
  • Stop using the device and contact [email protected] if you notice swelling, leakage, discoloration, or an unusual smell.
6 · Troubleshooting & support
SymptomFirst checkIf unresolved
No LED on hold-5sHold a full 5 seconds; try again. Confirm the unit is within labeled shelf lifeContact support with serial + order reference
LEDs go dark after ~30 minNormal power-save — short-press; a blink means it is still recordingIf short-press shows no response at all, contact support
Want to stop recordingNot supported — see §1.1 / why no stop
PC shows no PDF/CSVWait up to a minute; try another USB port; on Windows allow the removable drive. Bag must be opened for USBContact support; attach a photo of the device + port
Android does not see filesUse a USB-OTG adapter that supplies data (not charge-only); open the file managerRead out on a PC instead
Alarm LED on / unexpected chartCompare PDF min/max against the lane spec; check placement (door vs supply air)Contact support with the PDF/CSV

Before contacting support, have ready: order reference, device serial number(s), product model (C1), description of the fault, and evidence (photos / PDF / CSV) if available.

Contact: [email protected], or your local authorized Cydiance partner. Regional notes: Support in your region.

7 · Warranty (summary)
Full authoritative terms: Cydiance Hardware Warranty Terms (last updated 2026-07-01). This section is a summary only — if this manual and the web legal page differ, the web page governs.

7.1 Coverage

  • C1 hardware defects not caused by the customer, for the warranty period stated on the device label and your distributor agreement (12 months typical).
  • Warranty period starts on arrival at the distributor unless otherwise agreed in writing.
  • Within the labeled Shelf life / Service life, a battery-related failure preventing documented operation is warranty-eligible (subject to evaluation).

7.2 Exclusions (highlights)

  • Physical damage, unauthorized disassembly/modification/repair
  • Operation or storage outside the specified temperature ranges (§4)
  • Removed/defaced labels or serial numbers (including Shelf life / Service life markings)
  • Battery end-of-life wear after labeled Shelf life / Service life
  • Improper storage, installation, or shipment placement; bag removed in transit when IP67 was required
  • Cargo loss, spoilage, or business interruption — the C1 is a monitoring tool, not covered

7.3 How to request service

  1. Contact your authorized Cydiance partner or [email protected].
  2. Provide order reference, serial number(s), model (C1), and fault description.
  3. Wait for return authorization before shipping devices back — follow lithium-battery packaging/safety instructions (UN3091; see §5).
8 · C1 vs. other Cydiance loggers

C1 is the USB logger Cydiance puts in front. Need to read without opening the bag → B3. Need a screen or a probe → B5. Need live upload in transit → R3.

Full manuals: C1 · B3 · B5 · R3.

DimensionC1B3B5R3
UseSingle-use USBSingle-use USB + BLESingle-use USB + BLE + LCDReusable 4G (+2G fallback)
Range−30°C to +70°C−30°C to +70°C−30°C to +70°C−20°C to +55°C
Silent RecordsYesYesYesN/A (live upload)
ReadoutUSB PDF+CSVUSB or App (BLE)USB or App (BLE)Vista / App (cellular)
ScreenNone (2 LEDs)None (2 LEDs)LCDLCD + QR
ProbeNoNoYes (temperature needle or T/H — pick one)No
Weight14.5 g16.2 g28.1 g~145 g
BatteryCR2032CR2032CR2450Ni-MH rechargeable
Air notesIATA 970 Section II+ RTCA/DO-160G+ RTCA/DO-160GNi-MH (not lithium UN3481)

Questions about your C1? Contact [email protected].